Brand Name :Kreat Power
Model Number :KE002-03M180KB
Certification :CE
Place of Origin :China
MOQ :100pcs
Price :Negotiation
Payment Terms :T/T, Western Union
Supply Ability :10,000pcs per Month
Delivery Time :within 5 working days for sample and small order; within 3-4 weeks for bulk order
Packaging Details :Packed in bubble bags firstly, amd then reinforced with carton for outer packing
Emergency power :3W Max.
Emergency time :3 hours
Load output current :180-20mA
Load output voltage :20-60Vdc
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB

1. Features

--Constant power output LED emergency power supply, max 3W emergency power, and wide output voltage range.

--Multiple protection function: battery over charge , deep discharge, output overload and short-circuit protection.

2. Parameters

Charge Part Rated input voltage 220-240Vac 50Hz /60Hz
Rated input current 0.1A Max.@230Vac
Input inrush current 30A(230Vac full load)
Power factor ≥0.5W @230Vac
Input power <2W@230Vac
Battery charging current 240mA
Battery charging time 24 hours Max.
Emergency Part Operating mode Emergency
Load type LED
Emergency power 3W Max.
Emergency time 3 hours
Load output current 180-20mA
Load output voltage 20-60Vdc
Battery Type Li-ION: 3.7V 3350mAH
Exception Driver Requirements Surge current N/A
Input current N/A
Output current N/A
LED Indication Charging The green light turns on
Fault The green light switches off
Emergency Function Test Manual test Yes
Auto test N/A
Connect Control Bluetooth N/A
DALI N/A
Abnormal Protection Requirements Battery over-charge/deep discharge protection Yes
Output over-voltage protection Yes
Output overload protection Yes
Output no-load protection N/A
Output over-temperature protection N/A
Output short circuit protection Yes

Operating

Environment

Operating temperature/humidity 0℃…+50℃ humidity:20%-85%(without condensation)
Storage temperature/humidity -5℃…+45℃
Case Max. Temp(Tc) 75℃

Safety

& EMC

Withstand voltage 3750Vac 5mA 60S(Input “L N” – output “SEC+ SEC-)
Safety standard EN61347-1, EN61347-2-7
EMC standard EN55015, EN61000-3-2, EN61000-3-3
Battery standard EN61233
Environmental protection requirements Compliant to RoHS
Certification CE
Others Input/output(terminal/wiring) type Press terminal, wire diameter:0.5-0.75mm2
IP rating IP20
Type of protection Class 2
Installation type Built-in installation
Installation dimension 137*42*22mm
Packaging requirement Bubble bag+ clapboard +outer carton(K=A)
Weight 111g
Lifespan Emergency driver 30000h @Ta full load (Driver)

Notes:

All parameters are tested on the input voltage 120/230Vac,environment temperature 25℃,unless otherwise specified.

3. Dimension (Unit:mm)

LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB

4. Wiring Diagram

LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB

5. Function

LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB

6. Wire Preparation

LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB

1)Solid or Stranded wire type 0.5 - 0.75mm2

2)To make or release the wire from the terminal, use a screwdriver to push down the button.

7. Manual Test & Operation Instructions

1) Connect the wire according to wiring diagram.

2) L,N power on, switch on E. Then the load lamp turns on, the emergency driver indicator light will turns green, emergency power supply normal charging. Turn off this switch E, the load lamp will be extinguished.

3) Emergency Simulation: Switch on E, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of emergency driver will be extinguished. Release the switch(TEST SWITCH), then lamp is powered by led driver, the indicator light will turn on.

4) Power off and power on, the phenomenon should be similar to emergency simulation.

8. Battery Application Notice

1) The battery should be recharged and discharged semiannually in normal use conditions.

2) Do not connect to the circuit when the battery is not use to prevent over-discharge of the battery due to self-consumption of the circuit board.

3) Please keep the battery from the heat source when installing and using, and only be allowed to use in certain working temperature range.

4) The battery should be stored in a cool and dry environment.

5) After long time storage, the battery is cycled every 6 months as required.

6) If you don’t use for a long time(for example, in transport or in a warehouse), please press the REST button.

Inquiry Cart 0