Add to Cart
1. Features
1. Microwave motion detection version.
2. Eight DIP switch setting, distance, time, daylight sensor, multi-speed adjustable.
3. Ultra-small mounting size, multiple mounting options, support for top and bottom mounting options.
4. Super cost-effective, support a variety of lamps,tri-proof lamps, ceiling lamps.
5. The infrared sensor is used to filter out the light sensor, and the light sensitivity value is more accurate, and is not affected by cloudy and sunny days.
6. Low impedance 5.8G antenna for superior immunity to interference.
7. Batch over RED, TUV certification.
2. Parameter
Input | Operating Voltage Range | 198-264VAC 50/60Hz |
DC Input Voltage | N/A | |
Rated Voltage | 220-240VAC 50/60Hz | |
No-load Power | ≤1.0W | |
Stand-by Power | ≤0.5W | |
Surge Test | Between L and N: 1KV | |
Output | Working Mode | ON/OFF |
Type of Load | Resistive or Capacitive | |
Load Capacity | 800W (Resistive) or 400W (Capacitive) | |
Current of Load | N/A | |
Load surge current | 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load) | |
Interface | 1-10V dimmer | N/A |
Synchronization control interface | N/A | |
High and Low Level Interface | N/A | |
PWM control interface | N/A | |
Interface terminal wiring mode | N/A | |
Sensor | Operating Frequency | 5.8 GHz ±74.9 MHz.ISM wave band |
Transmitting power | 0.5mW Max. | |
Hold time | 5S/30S/60S/3min/5min/10min/20min/30min | |
DIM down | N/A | |
Cut off | N/A | |
Detection Area | 100% / 75% / 50% / 25% | |
Daylight Sensor | 2Lux/10Lux/25Lux/50Lux/Disable | |
Daylight on/off | N/A | |
Detecting Radius | 4-7m (Installed at 3m high ) | |
Mounting Height | 2.5-6 m(Suction Top Installation) | |
Detecting Angle | Ceiling mount 150° | |
Wireless module | Operating Frequency | N/A |
Transmitting power | N/A | |
transmission distance | N/A | |
modulation mode | N/A | |
Coding group number | N/A | |
Operating Environment | Operating Temperature | -20℃…+60℃ Humidity: 85% (non-condensing) |
Storage Temperature | -40℃…+80℃ | |
Certificate Standards | Safety standards | EN61058-1 |
EMC standards | EN300440, EN301489-1, EN55015, EN61547, EN61000-3-2, EN61000-3-3, EN62479 | |
Environmental Requirement | RoHS | |
Certificate | CE, TUV & RED | |
Others | Input/output terminal specifications | 0.5-0.75mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in installation | |
Dimension | 62*36*25mm | |
Package | Bubble bag + partition + outer box (K=A) | |
Net Weight | 36g | |
Lifetime | 50,000h @ Ta Full load | |
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. |
3. Dimension (mm)
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
4. Radiation Pattern
Ceiling mounting
*50%,75%,100% detection sensitivity is workable when installed at 6m mounting height. Only 25% sensitivity is not able to detect motion signal.
Wall mounting:
5. Function Dialing Settings
Detection Area
1 | 2 | ||
Ⅰ | ON | ON | 100% |
Ⅱ | ON | - | 75% |
Ⅲ | - | ON | 50% |
Ⅳ | - | - | 25% |
3 | 4 | 5 | ||
Ⅰ | ON | ON | ON | 5S |
Ⅱ | ON | ON | - | 30S |
Ⅲ | ON | - | ON | 1min |
V | ON | ON | - | 3min |
IV | - | ON | ON | 5min |
IIV | - | ON | - | 10min |
ⅢV | - | - | ON | 20min |
IX | - | - | - | 30min |
Daylight Sensor
6 | 7 | 8 | ||
Ⅰ | ON | ON | ON | 2Lux |
Ⅱ | ON | ON | - | 10Lux |
Ⅲ | - | ON | - | 25Lux |
V | ON | - | - | 50Lux |
IV | - | - | - | Disable |
6. Override Function
Quick switch ON/OFF 3 times within 2sec to override sensor function. Lights will switch on all the time. Power off and on again to recover sensor function.
7. Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.
8. Factory settings
Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable
9. Use Caution
1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.
2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.
3. It has to be at least 3.5mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.