
Add to Cart
LifePO4 6.4V 1800mAh built-in battery electronic led converter for LED panel or LED downlight
1. Description
1) Constant Power Output: Experience consistent and reliable power supply for your LED lighting systems, ensuring uninterrupted illumination.
2) Input/Output Relay Switching: Seamlessly switch between normal and emergency modes during power outages for continuous lighting operation
3) Multiple Protection Functions: Benefit from battery overcharge and over-discharge protection, along with output short circuit protection for enhanced safety.
4) Built-in Battery, Easy Replacement: Enjoy the convenience of a built-in battery with easy replacement, ensuring hassle-free maintenance.
2. Parameters
Charge Part | KE006 | KE006-02M180HB | KE006-03M180HB |
KE006-02A180HB | KE006-03A180HB | ||
Rated input voltage | 220-240Vac 50Hz /60Hz | ||
Rated input current | 0.05A Max. @230Vac | ||
Input inrush current | 10A(Twidth=100uS 50% Ipeak )@230Vac(Cold start at full load ) | ||
Power factor | ≥0.5@230Vac | ||
Input power | <4W | ||
Battery charging current | 200mA Max | ||
Battery charging time | 24 hours Max | ||
Emergency Part | Operating mode | Emergency mode | |
Load type | LED | ||
Emergency power | 2W | 2.5W | |
Emergency time | 3 hours | ||
Load output current | 100-30mA | 150-45mA | |
Load output voltage | 20-60VDC | ||
Battery | LifePO4 (The battery capacity meets the emergency time at 25℃) | 6.4V 1800mAh | |
Battery warranty | Warranty 3 years, Design Life 5 years. | ||
Exception Driver Requirements | Surge current | 8A | |
Input current | 3 A Max. | ||
Output current | 3 A Max. | ||
LED Indication (Manual test) | Charging | Greenlight | |
Fault | Green light off | ||
Emergency Function Test | Manual test | KE006-02M180HB / KE006-02M180HB | |
Autotest | KE006-02A180HB / KE006-02A180HB | ||
Auto Testing | Fault/test / Status | Reason | Charge Indicator Status |
Battery fully charged and operational | Standard daily use | ||
solid green | |||
Battery Charging | Initial Charge/Battery Top Up | ||
solid green | |||
Auto Test 3 Hours (every 12 months) | Periodic self-test | ||
Flashing Green 3 sec on 1 sec off | |||
Auto Test 5 Min (every 30 days) | Periodic self-test | ||
Flashing Green 3 sec on 3 sec off | |||
Duration test fault | Failed the 3-hour annual test | ||
Flashing Red 0.5 sec on 0.5 sec off | |||
LED fault | Not plugged in or damaged/faulty | ||
Flashing Red 2 sec on – 2 sec off | |||
Battery Disconnected/Faulty | Not plugged in or damaged/faulty | ||
solid red | |||
Abnormal protection | over-charge/deep discharge protection | Yes | |
Output over-voltage protection | Yes | ||
Output overload protection | Yes | ||
Output short circuit protection | Yes | ||
Operating Environment | Operating temperature/humidity | 0℃…+50℃; humidity:20%-75%(without condensation) | |
Storage temperature/humidity | -5℃-35℃ | ||
Case Max. Temp(Tc) | 75℃ | ||
Safety & EMC
| Withstand voltage | 3000Vac 5mA 60S (Input “L N” – output “SEC+ SEC-) | |
Safety standard | EN61347-1, EN61347-2-7 | ||
EMC standard | EN55015, EN61000-3-2, EN61000-3-3 | ||
Battery standard | UN38.3 | ||
Environmental protection requirements | Compliant to RoHS | ||
Certification | CE | ||
Others | In/output(terminal/wiring)specification | Press terminal, wire diameter:0.75-1.5mm2 | |
IP rating | IP20 | ||
Type of protection | Class 2 | ||
Installation type | Built-in installation | ||
Installation dimension | 211*42.5*25mm | ||
Packaging requirement | White box+Instruction manual+clapboard+outer carton(K=A) | ||
Weight | 200g; | ||
Lifespan | 5 Year @Ta ( Battery not included ) | ||
Notes: All parameters are tested on the input voltage 230Vac, environment temperature 25℃ unless otherwise specified. |
3. Dimension (Unit:mm)
4. Wiring Diagram
OR
5 . Manual Test & Operation Instructions
1). Connect the wire according to the wiring diagram.
2). L, N power on, Switch on S1. then the load lamp turns on, The emergency driver indicator light turns green, emergency power supply normally charging. Turn off Switch S1, and the load lamp turns off.
3). Emergency Simulation: Switch on, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of the emergency driver will be extinguished. Release the switch(TEST SWITCH), then the lamp is powered by the LED driver, the indicator light will turn on.
7. Battery Application Notice
1)The battery should be recharged and discharged semiannually in normal use conditions.
2)Do not connect to the circuit when the battery is not used to prevent over-discharge of the battery due to self-consumption of the circuit board.
3)Please keep the battery from the heat source when installing and using it, and only be allowed to use it in a certain working temperature range.
4)The battery should be stored in a cool and dry environment.
5)After a long time of storage, the battery is cycled every 12 months as required.