Shenzhen Merrytek Technology Co., Ltd.

Shenzhen Merrytek Technology Co., Ltd Intelligent Lighting Control

Manufacturer from China
Verified Supplier
11 Years
Home / Products / Dimmable Motion Sensor /

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

Contact Now
Shenzhen Merrytek Technology Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsJune Zhao
Contact Now

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

Ask Latest Price
Video Channel
Brand Name :Merrytek
Model Number :MC049V R
Certification :CE, RED,TUV
Place of Origin :China
MOQ :300pcs
Price :Negotiation
Payment Terms :T/T or western Union
Supply Ability :20,000pcs per month
Delivery Time :1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Packaging Details :Bubble bag+ Clapboard+ Carton(K=A)
Rated voltage :120-277V AC
Stand-by power :≤0.5W (230Vac)
Working mode :ON/OFF 1-10V dimming
Installation Requirement :Built-in
Load capacity :120Vac 400W(inductive or resistive) 220Vac-240Vac 800W(inductive or resistive) 277Vac 1000W(inductive or resistive)
Certificate :CE, RED,TUV
Life time :5 years warranty @Ta 230V full load
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height, With Sync ON/OFF Function

1. Features

  • Standard product, with 1-10V LED dimming drive, achieve 2-step or 3 step dimming function with 1-10V dimmable led driver,with a synchronous end
  • Detection area,hold time,daylight sensor,stand-by period,dim level by DIP switch
  • Convenient connection for user by pressed terminals for input and output end

2. Parameters

Input Operating voltage 108-305V AC 50Hz/60Hz
Rated voltage 120-277V AC
Stand-by power ≤0.5W(230Vac)
Output Working mode ON/OFF 1-10V dimming
Type of load White woven light/power supply /1-10V LED light
Load capacity

120Vac 400W(inductive or resistive)

220Vac-240Vac 800W(inductive or resistive)

277Vac 1000W(inductive or resistive)

Max.surge capacity 30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start); 60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
Dim interface 1-10V Dimming Available
Syn control Available(Can sync for on-off function,can’t sync for 1-10V dimming )
Sensor parameters Operating frequency 5.8 GHz ±75 MHz,ISM band
Transmitting power 1mW Max.
Detection Area 25%/50%/75%/100%(by two DIP switches)
Hold time 5s/30s/90s/3min/20min/30min(by three DIP switches)
Stand-by dim Level 10%(1.4-1.6V)/20%(1.9-2.1V)/30%(2.9-3.1V)/50%(4.9-5.1V)(by two DIP switches)
Stand-by Period 0S/5S/5min/10min/30min/1h/+∞(by three DIP switches)
Daylight Sensor 2 lux/5Lux /10Lux /25Lux /50Lux /100Lux /Disable(by four DIP switches)

Detection Range

(100% Sensibility Radius)

Surface mounting 3m height:0.3m/S ≥3.5m,1m/S ≥2.5m

Horizontal mounting 2m height:0.3m/S ≥8m,1m/S ≥4m

Mounting height 3m(6m max)

3db beam Angle

80°@XZ plane

96°@YZ plane

Operating envrionment Operating Temperature -25℃~70℃
Storage Temperature/humidity -40℃~80℃ humidity:≤85% (non-condensation)
Certificate Standards Safety(LVD) standards EN61058-1,EN61058-1-2,
lightning surge 1KV(L/N,EN61000-4-5)
EMC standards

EN61058-1,EN61000-3-2,EN61000-3-3,EN62479,

EN301489-1,EN55015,EN300440

Environmental Requirement Compliant to RoHS
Certificate CE, RED,TUV
Others Input/Output(connector/wiring)specification Press-in terminals wire diamter:0.75-1.5mm2
Installation Requirement Built-in
Installation Dimension 180*50*30mm
Package Requirement Bubble bag+ Clapboard+ Carton(K=A)
Net weight 75g
Life time 5 years warranty @Ta 230V full load

3. Parameters

1. On-off function(Stand-by Period “0s”)

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

2. 2-step dimming function(Stand-by Period“+∞”)

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

3. 3-step dimming function(Stand-by Period“5s/5min/10min/30min/1h”)

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

4. Dimension (mm)

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height
5. Wiring
1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height
6. Structure
1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height
7. Structure
1. Detection Area
1 2
ON ON 100%
ON - 75%
- ON 50%
- - 10%
2. Hold Time
3 4 5
ON ON ON 5S
- ON ON 30s
ON - ON 90S
- - ON 3min
ON ON - 20min
- - - +∞

3. Stand-by Period

6 7 8
ON ON ON 0S
- ON ON 5S
ON - ON 5min
- - ON 10min
ON ON - 30min
- ON - 1H
VII - - - +∞

4. Daylight Sensor

1 2 3 4
- - ON ON 2Lux
- - - ON 5Lux
- ON ON - 10Lux
- - ON - 25lux
- ON - - 50lux
ON - - - 100lux
VII - - - - Disable

* When set to Disable, the sensor will turn on the light when it detects movement, regardless of whether the light is sufficient.

* Daylight threshold value is the typical value under the condition of sunny environment, no shading, diffuse reflection of ambient light.

5. 1-10V(Stand-by DIM Level)

5 6 Brightness%
ON ON 50%
- ON 30%
ON - 20%

-

- 10%
8. Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 10 seconds, it turns off the light. During the initialization, the sensor is not able to detect movement
9. Factory setting
Detection area: 100%, Hold time: 5s, Stand-by Period: 0s, Daylight Sensor: Disable
10. Application notice

1) The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.

2) Microwave cannot penetrate metal, please avoid installing the product in closed or semi-closed metal lamps, and ensure that there is no metal or glass shield above the product; If the antenna must pass through the metal plate, ensure that the top of the sensor is close to the metal plate.

3) The installation distance between microwave sensors is recommended to be greater than 3m, and should be far away from switches, routers and other wireless devices to avoid radio interference. The installation distance between both is recommended to be greater than 2m; The antenna surface of the microwave sensor must be far away from the input AC and output DC to avoid interference from low/high frequency signals.

4) Long-term vibration equipment or moving objects should be avoided around the microwave sensor. The vibration signal generated will be regarded as mobile signal triggering induction. If a pet passes by in the test area, the sensor may be triggered.

5)This product is suitable for indoor installation,if for semi-outdoor or outdoor installation, wind and rain may be regarded as a mobile signal trigger induction; When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.

6)This model is suitable for ceiling installation. If wall installation is used, the microwave induction detection distance will be greatly increased, which may lead to microwave penetration through the wall or the lamp will not be off. Please adjust the sensitivity by 25%. If 25% cannot be used, avoid wall installation or contact the manufacturer for technical support.

7)Product specifications and parameters may be optimized without prior notice.

8) The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection.Lux level detected by sensor could be different in different period and climate condition.

9) Product detection range is related to the moving speed of the object, the size of the object, the installation height of the product, the installation angle, the installation environment, the material of the reflection and other factors.

10) The detection distances given in the specifications are typical values, which are obtained by testers in an indoor open environment of 165cm/65kg.

11) Do not put the sensor near high-density objects, such as metal, glass, mixed walls, etc., because the sensor may trigger incorrectly.

12) Sensor parameters may need to be reconfigured in different installation environments. Please refer to the above instructions or contact the manufacturer.